Analyzing the synthesis route of 494-52-0

I hope my short article helps more people learn about this compound((S)-3-(Piperidin-2-yl)pyridine)Safety of (S)-3-(Piperidin-2-yl)pyridine. Apart from the compound(494-52-0), you can read my other articles to know other related compounds.

Epoxy compounds usually have stronger nucleophilic ability, because the alkyl group on the oxygen atom makes the bond angle smaller, which makes the lone pair of electrons react more dissimilarly with the electron-deficient system. Compound: (S)-3-(Piperidin-2-yl)pyridine, is researched, Molecular C10H14N2, CAS is 494-52-0, about Automated Solid Phase Extraction and Polarity-Switching Tandem Mass Spectrometry Technique for High Throughput Analysis of Urine Biomarkers for 14 Tobacco-related Compounds.Safety of (S)-3-(Piperidin-2-yl)pyridine.

Tobacco use is the leading preventable cause of premature disease and death in the United States. Approx., 34 million U.S. adults currently smoke cigarettes. We developed a method for automated sample preparation and liquid chromatog.-tandem mass spectrometry quantitation of 14 tobacco-related analytes: nicotine (NICF), cotinine (COTF), trans-3′-hydroxycotinine (HCTF), menthol glucuronide (MEG), anabasine (ANBF), anatabine (ANTF), isonicoteine (ISNT), myosmine (MYOS), beta-nicotyrine (BNTR), bupropion (BUPR), cytisine (CYTI), varenicline (VARE), arecaidine (ARD), and arecoline (ARL). The method includes automated solid-phase extraction using customized pos.-pressure functions. The preparation scheme has the capacity to process a batch of 96 samples within 4 h with greater than 88% recovery for all analytes. The 14 analytes, separated within 4.15 min using reversed-phase liquid chromatog., were determined using a triple-quadrupole mass spectrometer with atm.-pressure chem. ionization and multiple reaction monitoring in neg. and pos. ionization modes. Wide quantitation ranges, within 1.2-72,000 ng/mL, were established especially for COTF, HCTF, MEG, and NICF to quantify the broad range of biomarker concentrations found in the U.S. population. The method accuracy is above 90% while the overall imprecision is below 7%. Finally, we tested urine samples from 90 smokers and observed detection rates of over 98% for six analytes with urinary HCTF and MEG concentrations ranging from 200-14,100 and 60-57,100 ng/mL, resp. This high throughput anal. process can prepare and analyze a sample in 9 min and along with the 14-compound analyte panel can be useful for tobacco-exposure studies, in smoking-cessation programs, and for detecting changes in exposure related to tobacco products and their use.

I hope my short article helps more people learn about this compound((S)-3-(Piperidin-2-yl)pyridine)Safety of (S)-3-(Piperidin-2-yl)pyridine. Apart from the compound(494-52-0), you can read my other articles to know other related compounds.

Reference:
Metal catalyst and ligand design,
Ligand Template Strategies for Catalyst Encapsulation – NCBI